- Shandong Brawny Industrial Co.,Ltd
- This is a verified supplier can provide quality products and have passed the Business License Check.
Home>Products>open diesel generator set>CGF2800X open type diesel generator set 2kw~10kw
CGF2800X open type diesel generator set 2kw~10kw
- open diesel generator set
open diesel generator set
- China
- One set CGF2800X open type diesel generator set 2kw~10kw
- [email protected]
- Within 5 working days
- paypal,UnionPay, Visa/MasterCard, Amex, Discover,T/T
- 153
- Shandong Brawny Industrial Co.,Ltd2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
Product Description
CGF2800X open type diesel generator set 2kw~10kw
Product Description
CGF2800X open type diesel generator set 2kw~10kw description:
Application:
CGF2800X open type diesel generator set 2kw~10kw mainly apply to field operation power generation, mobile and portable power generation.
Feature:
- Constant voltage AVR control germany technology
- Heat insulation F class insulation heat resistant 155 citi degree
- Security intelligence smart oil alarm automatic locking waterproof plug
- Portable, pure copper motor, thickening frame
The detail technical datas of CGF2800X open type diesel generator set 2kw~10kw
The Detail Technical Datas | ||||
---|---|---|---|---|
Model | CGF2800X-G-341 | |||
Rated frequency (Hz) |
50 | 60 | ||
Rated output (KVA) |
1.7 | 2.0 | ||
Max output (KVA) |
2.0 | 2.2 | ||
Rated volatage (V) |
115 | 230 | 120 | 240 |
Rated current (A) |
14.8 | 7.4 | 16.7 | 8.3 |
Rated speed (r/min) |
3000 | 3600 | ||
Number of phase | 1 | |||
Power factor (Cosφ) |
1 | |||
Insulation class | F | |||
Dimensions L x W x H (mm) |
640x460x525 | |||
Net weight (kg) |
63 | |||
Engine type | CG170FB | |||
Starting system | starting hand or electric starter | |||
Fuel type | summer: use NO.0, winter: use NO.-10 or NO.-20 | |||
Lubricants type | summer: use CC15w/40, winter: use CC15w/30 | |||
Oil capacity (L) |
0.75 | |||
Red electric capacity (V-Ah) |
X: / E:12V general batteries /22Ah | |||
Fuel tank capacity (L) |
13.5 | |||
Continuous operation time of unit (h) |
10 |
Different kinds of diesel generator sets
Model | CGF4000X 3KW | CGF6700E 5KW |
CGF6700T3 5KW | CGF7500E3 | CGF8500E 8KW | CGF12E3 10KW | ||||||||||||||||||
Rated frequency(Hz) |
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | ||||||||||||
Rated output(KVA) | 2.6 | 3.0 | 4.5 | 5.0 | 5.5 | 6.3 | 6.5 | 6.9 | 6 | 6.5 | 10 | 11 | ||||||||||||
Max output (KVA) | 2.8 | 3.2 | 5.0 | 5.5 | 6 | 7.5 | 6.9 | 7.5 | 6.5 | 7 | 11 | 12 | ||||||||||||
Rated volatage(V) | 115 | 230 | 120 | 240 | 115 | 230 | 120 | 240 | 230 | 400 | 240 | 416 | 230 | 400 | 240 | 416 | 150 | 230 | 120 | 240 | 230 | 400 | 240 | 416 |
Rated current (A) |
22.6 | 11.4 | 25 | 12.5 | 31.9 | 19.6 | 41.7 | 20.8 | 7.9 | 8.7 | 9.4 | 9.6 | 52 | 26 | 54 | 27 | 18.1 | 19.1 | ||||||
Rated speed (r/min) | 3000 | 3600 | 3000 | 3600 | 3000 | 3600 | 3000 | 3600 | 3000 | 3600 | 3000 | 3600 | ||||||||||||
Number of phase | 1 | 3 | 1 | 3 | ||||||||||||||||||||
Power factor (Cosφ) |
1 | 0.8 | 1 | 0.8 | ||||||||||||||||||||
Insulation class | F | |||||||||||||||||||||||
Dimensions L x W x H (mm) |
660x460x545 |
700x490x610 |
910x530x740 |
700x490x610 |
920x660x850 | |||||||||||||||||||
Net weight (kg) | 71 | 104 | 171 | 106 | 110 | 208 | ||||||||||||||||||
Engine type | GG178F | CG186FA |
CG188FB |
CG192F | CG290F | |||||||||||||||||||
Starting system | Hand starting |
Electricity starting |
||||||||||||||||||||||
Fuel type | summer: use NO.0, winter: use NO.-10 or NO.-20 | |||||||||||||||||||||||
Lubricants type | summer: use CC15w/40, winter: use CC15w/30 | |||||||||||||||||||||||
Oil capacity (L) |
1.1 |
1.65 | ||||||||||||||||||||||
Red electric capacity (V-Ah) |
X: / E: 12V general batteries/24Ah |
X: / E: 12V Apollo 24Ah |
X: / E: 12V Apollo 24Ah |
X: / E: 12V Apollo 24Ah |
X: / E: 12V Apollo 36Ah |
X: / E: 12V Apollo 36Ah |
||||||||||||||||||
Fuel tank capacity(L) |
13.5 | 17 | 13.5 | 30 | ||||||||||||||||||||
Continuous operation time of unit(h) |
8.5 | 6 | 5 | 4.5 | 5 |
If you are interested in knowing more details, or the CGF2800X open type diesel generator set 2kw~10kw messages, please click on the product in the picture or the following link:
https://cg-dl.en.CGF2800X open type diesel generator set 2kw~10kw.com/?spm=a2700.7756200.1998619056.12.jDryWD.
Details of CGF2800X open type diesel generator set 2kw~10kw
Product flow Packaging & Shipping Company Information Trade Shows Certifications FAQ
Black smoke
1. Over load of diesel engine.
2. Oil supplying time is too late.
3. Too excessive oil supply.
4. Poor atomization of injector.
5. Poor compression (leakage of air valve, cylinder sleeve or cylinder gasket)
6. Clogging of inlet or exhaust pipe.
7. Too large gap between air valves, and the opening of air valve is too small.
8. Too much deposited carbon in combustion chamber.
9. Oil pressure is insufficient, CGF2800X open type diesel generator set 2kw~10kw to burning and clasping of bearings.
10. Pull cylinder, and pull piston are broken.
Blue smoke
The gap between piston and sleeve is too large and replaced piston can’t match cylinder sleeve.
1. Oil ring is stuck in track, causing piston rings arrange in same line, or broken, or seriously scuffed, CGF2800X open type diesel generator set 2kw~10kw the opening of oil ring is too big.
2. Heavy scuffing on air valve rod and air valve guide.
3. Oil surface is too high on the bottom of engine.
4. Oil surface of oil pan in filter is too high.
5. Diesel is mixed with engine oil.
White smoke
1. Water is mixed in diesel.
2. Cylinder head gasket is broken or the surface of cylinder head has notches, making the cooling seepg into the cylinders.
3. The temperature of engine is too low, and it is put on load without preheating.
4. When diesel engine is started with empty load after being cooled, due to poor injector atomization, excessive spray of oil and other reasons, the diesel in the cylinder can’t be complete combusted, this part of diesel turn into a white gas, and then discharged by the exhaust pipes.
Why does abnormal sound occur in the operation of engine?
1. Too large sir valve gap.
2. Too large gap between air valve rod and valve guide.
3. Two small air valve gap or too high air valve seat, causing air valve to hit piston.
4. Valve guide is broken.
5. Serious leakage of air valve.
6. Cylinder head gasket or installment point of injectors leaks air.
7. Internal barriers of silencer or internal pipe with holes fall or break.
8. Too large gap between piston and cylinder sleeve.
9. Too large gap between piston pin and copper linings.
10. Two early supply of oil.
11. Two late supply of oil.
12. Two large gap between connecting rod neck and connecting rod bearing, main bearing and main bearing neck.
13. Connecting rode bolt is loose.
14. Head of connecting rod neck collides with upper and lower balance bearings and connecting rod neck collides with cam.
15. Axial clearance of crankshaft is too large.
16. Flywheel is loose.
17. Upper and lower balance bearing are loose.
18. Gear gaps are too big, gap between sleeve and couple are too large.
19. Inlet and exhaust of camshaft has serious scuffing, and rising life is lowered too much, there are notches on the contact surface of air valve tappet with cam, which reduce the opening degree of air valve, and cause the sound “pa pa” happens.
Why does cooling tank have engine oil and black carbon?
1. There are cracks on the cylinder head and engine body.
2. Water seal ring of cylinder sleeve is broken.
3. Cylinder gasket is uneven in thickness or damaged.
4. Water head of cylinder is damaged.
Why is engine temperature too high and why is it easily to boil cooling water?
1. The gap between every moving parts is too nCGF2800X open type diesel generator set 2kw~10kw, and galling effects occurs.
2. Poor lubrication
3. Too much deposited carbon in combustion chamber reduce heat dissipation
4. Incrustation in water tank is too thick, and water channel is blocked, affecting heat dissipation.
5. Lack of water
6. Too late supply of oil
7. Diesel engine operates overloaded.
8. Poor atomization of injector cause diesel engine emits black smoke.
9. Poor ventilation and high environmental temperature affects diesel heat dissipation.
Contact Information
open diesel generator set is powered by series Diesel Engine.CGF2800X open type diesel generator set 2kw~10kw has the feature of good power performance,safety,low fuel consumption and good reliability.This series generator set is widely used as prime or standby power supply in fieldwork,building,supermarket,industrial and mining factory,oil field,highway,harbour and so on.
JHBJHGJ
open diesel generator set that we provide are all new, each unit all get through the strict production testing.
CGF2800X open type diesel generator set 2kw~10kw 12 months or 1000 hours(whichever occurs first) of Warranty Time for all our CGF2800X open type diesel generator set 2kw~10kw. We take the full responsibility only in the fault that created by the quality, the wearing-parts, daily consumables and human error of operating & maintenance are not included in.
Contact Us
- Shandong Brawny Industrial Co.,Ltd
- Phone(Working Time)
Product Categories
New Products
- 10kw open diesel generator set
- power silent diesel generator guangzhou price sale genset generator set 10kva parkins silent type diesel generator
- Promotional Deutz water cooled diesel generator set with best price
- buy direct china AOSIF High performance diesel power generator dg set
- 1600kw 2000kva diesel generator set powered by 4016TAG2A