Googol Diesel Gas Blend Engine 800kW 1000kVA Dual Fuel Power Generation
Genset Model | HDGM1100 | |
Engine Model | QTA2160BG1 | |
Rating Speed | rpm | 1500 |
Frequency | Hz | 50 |
Generator Continuous Output (COP) | kW | 720 |
Generator Prime Output (PRP) | kW | 800 |
Generator Standby Output (LTP) | kW | 880 |
Power Factor | 0.8 | |
Gas Engine Parameter | ||
Engine Continuous Output (COP) | kW | 804 |
Engine Prime Output (PRP) | kW | 952 |
Engine Standby Output (LTP) | kW | 1058 |
Configuration | 8 Vee | |
Displacement | l | 35.4 |
Bore | mm | 170 |
Stroke | mm | 195 |
Compression Ratio | 13.5:1 | |
Piston Speed | m/s | 9.75 |
Number of Flywheel Teeth | 218 | |
Flywheel House Size | SAE00-18 | |
System Parameter | ||
Oil Capacity | l | 160 |
Max. Allowed Oil Temperature | °C | 110 |
Oil Pressure Warning | kPa | 300 |
Oil Pressure Shutdown | kPa | 200 |
Coolant Capacity for Engine | l | 70 |
Max. Coolant Warning Temperature | °C | 93 |
Max. Coolant Shutdown Temperature | °C | 97 |
Flow of Coolant pump | m³/h | 48/45 |
Max. Exhaust Temperature | °C | 545 |
Exhaust Flow | m³/min | 225 |
Exhaust Flange Diameter | mm | 250 |
Charging Alternator Capacity | A | 55 |
Starting Voltage | V | 24 |
Fuel & Gas Consumption (PRP) | ||
Fuel Consumption at 75% Load | l/h | 49 |
Gas Consumption at 75% Load | m³/h | 132 |
Fuel Consumption at 100% Load | l/h | 66 |
Gas Consumption at 100% Load | m³/h | 175 |
Generator Parameter-MECC ALTE | ||
Generator Model | ECO43-1LN/4 | |
Generator Prime Output | kW | 880 |
Generator Efficiency @ 0.8PF | 95.8% | |
Genset Dimension | ||
Length | mm | 4600 |
Width | mm | 2190 |
Height | mm | 2300 |
Genset Weight | kg | 7650 |
Standard Supply Scope:
Googol Dual Fuel engine with alternator, 400V, 1500rpm, 50Hz
Air/Gas Mix System: Air/gas mixer, Controller, Pressure sensor
Governor System: Governor controller, Throttle, Sensor,
Gas Train:Ball Valve, Gas filter, Gas Regulator, Gas Control Valve
Gas Low Heat Value: ≥ 36MJ/Nm3
Maximum Gas Propotion: 70%
Applied gas:
Natural Gas,
Acceptable fuel gas pressure: 5~12kPa
CH4 content: for natural gas≥85% CH4 ,content:for biogas≥40%
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value
Gas doesn’t include free water or free materials (the size of impurities should be less than 5μm.)
H2S content≤200mg/Nm³
NH3 content≤20mg/Nm³
Impurities content≤30mg/Nm³;size≤5μm
Water content≤40g/Nm³, no free water.
Acceptable working conditions:
Ambient temperature : -10°C~+40°C
(antifreeze or preheater needed for below 0°C)
Relative humidity:
Altitude:≤1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%.
Performance Feature
Engine and alternator shall be mounted on a same frame steel skid.
Built-in damper for anti-vibration.
World most famous brand diesel engine.
World famous brand AC alternator.
Advanced and reliable control module
Full range protection function and alarm shutdown feature.
Alternator Feature
Brush-less, 4 poles, rotation magnet.
IP21-23(NEMA1) enclosure is standard for all industrial alternators.
The insulation system is Class H
Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.
Wide range of flange adaptors and single bearing disc coupling.
Standard 2/3 pitch windings avoid excessive neutral currents
AVR auto voltage regulator, auto exciter, auto adjustment
Standard Accessory
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.
Optional Accessory
Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, and Moving Trailer.
Silent Canopy Description
Standard Accessory:
Steel Weatherproof Canopy
Built In Fuel Tank For 8 Hours Running
Built In Control Panel
Built In Start Battery
Power Output Rapid Insert
Windows for Looking
Air Louver for Intake & Exhaust
Exhaust Gas Silencer
Soundproof Type
Quality Warranty Period:
All equipment is guaranteed for a period of 1000 hours running or 12 months from the date when the generator set has been delivered from the factory.
ATS System
For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically.
Generator Engine OEMs:
Generator Alternator OEMs:
Honny Power Certificates:
Honny Power Introduction:
The air-cooled diesel generator can have optional wheels and hand kits, Electric start or manual starting.Small-sized diesel generator sets includes open type and silent type.Our Googol Diesel Gas Blend Engine 800kW 1000kVA Dual Fuel Power Generation adopt different diesel engines and brushless generators.Generally adopt 1-cylinder&4-stroke&air-cooled engine, low fuel consumption, high reliability;It is easy to maintain as adopting brushless A.C.Generator and CDI ignition system.
JHSBJDHV
air-cooled diesel generator are quick-starting, stable-running, little vibration, low noise, light weight, small volume, compact structure, suitable for areas on mining, factory, working on field, engaging in construction and army as movable power or electric power in ship, Googol Diesel Gas Blend Engine 800kW 1000kVA Dual Fuel Power Generation also suitable for areas on animal husbandry, fishery, forest, orchard, guesthouse and business as standby power.
JSHFDKJ
Contact Us
- Shandong Brawny Industrial Co.,Ltd
- Phone(Working Time)